Model |
ASR 9922 |
ASR 9912 |
ASR 9910 |
ASR 9904 |
ASR 9006 |
ASR 9001 |
Slots |
20 Line Cards |
8 Line Cards |
8 Line Cards |
2 Line Cards |
4 Line Cards |
Fixed 4x10GE |
|
2 RPs |
2 RPs |
2 RSPs |
2 RSPs |
2 RSPs |
2 Modular Port Adapters |
|
7 Fabric Cards |
7 Fabric Cards |
5 Fabric |
-- |
-- |
|
Rack Size |
44 RU |
30 RU |
21 RU |
6 RU |
10 RU |
2 RU |
Bandwidth Per Slot |
|
|
4 Tbps |
770 Gbps |
|
|
Max Capacity |
160 Tbps |
80 Tbps |
64 Tbps |
16 Tbps |
7 Tbps |
240 Gbps |
Size (H×W×D) |
75.25 in.×17.75 in.×28.65 in. |
52.5 in.×17.60 in.×29.37 in. |
36.688 in.×17.60 in.×31.266 in. |
30.38 in.×17.75 in.×25 in. |
17.5 in.×17.5 in.×28.65 in. |
3.5 in.×17.5 in.×18.5 in. |
Power |
AC: 6 kW or 3 kW power modules |
AC: 6 kW or 3 kW power modules |
AC: 6 kW power module |
AC: 3 kW power module |
AC: 3 kW power module |
AC or DC |
DC: 4.4 kW or 2.1 kW power modules |
DC: 4.4 kW or 2.1 kW power modules |
DC: 4.4 kW power module |
DC: 2.1 kW power module |
DC: 1.5 kW or 2.1 kW power modules |
425 W (typical), 525 W(max) |
Note: Mixing of AC and DC modules is not supported |
Note: Mixing of AC and DC modules is not supported |
Note: Mixing of AC and DC modules is not supported |
Note: Mixing of AC and DC modules is not supported |
Note: Mixing of AC and DC modules is not supported |
|
Fan |
4 fan trays |
2 fan trays |
2 fan trays |
1 fan tray |
2 fan trays |
1 fan tray |
Airflow |
Front to Back |
Front to Back |
Front to Back |
Side to Side (Front to Back Option) |
Side to Side (Front to Back Option) |
Side to Side |
RSP/RP |
2 RPs |
2 RPs |
2 (1+1 RSP redundancy) |
2 (1+1 RSP redundancy) |
2 (1+1 RSP redundancy) |
Integrated |
Fabric Architecture |
Up to 6+1 fabric redundancy |
Up to 6+1 fabric redundancy |
Up to 6+1 fabric redundancy |
1+1 fabric redundancy |
1+1 fabric redundancy |
Integrated |
Software |
IOS XR |
IOS XR |
IOS XR |
IOS XR |
IOS XR |
IOS XR |
Features |
● Ethernet Services |
● L2VPN |
● IPv4, IPv6, and L3VPN |
● Layer 2 and Layer 3 multicast |
● IP over dense wavelength-division multiplexing (IPoDWDM) |
● Synchronous Ethernet (SyncE) |
● Ethernet operations, administration, and maintenance (EOAM) and MPLS OAM |
● Layer 2 and Layer 3 access control lists (ACLs) |
● Hierarchical quality of service (HQoS) |
● MPLS traffic engineering fast reroute (MPLS TE-FRR) |
● Multichassis link aggregation (MC-LAG) |
● Integrated routing and bridging (IRB) |
● Cisco Nonstop Forwarding (NSF) and nonstop routing (NSR) |
Environmental conditions |
● Operating temperature: 32 to 104°F (0 to 40°C) |
● Storage temperature: -40 to 167°F (-40 to 75°C) |
● Relative humidity: 10 to 90%, noncondensing |
● Regulatory compliance |