Features
· Simple Structure
· No Moving Part
· Reliable
· Durable with one Echelon Vortex Generator
· Output is proportional with flow rate
· The two pieces piezoelectric components are used to tests the vortex being not contact with the medium
· Liquid, gas and vapor could be measured by transmitters with same structure
· The mediums under all temp. And pres. Could be measured
Medium Measuring Range
Liquid, Gas, Steam refer to the flow rate form
Accuracy (of indicating value)
- Standard
Liquid: +/1.0%
Gas: +/-1.0% (velocity< 35m/s)
Steam: +/-1.0%(velocity 35m/s~70m/s)
Special
Liquid: +/-0.5%
Repeatability Fluid Tempt.
0.3% of indicating value - Standard: -40° C~+160° C
- High: +280° C
Rated Pressure Mount Type
DN15~DN200 PN4.0MPa Integral Flange/ Integral Clamp
DN250~DN300 PN2.5MPa
Environment Tempt. Humidity
-20° C~+60° C no more than 85%RH
Voltage Output Signal
24VDC +/-10% 2-wire; 4~20mA(24VDC)
Material
Housing: SS304
Body, Vortex Generator SS304, SS316, SS316L
Hazardous Classification
Exia IICT5; Exd IICT5
Bore: DN (mm)
Liquid: Qvmax[m 3 /h] | |
15 | 0.4-4.0 |
20 | 0.6-8.0 |
25 | 1.0-12 |
32 | 1.8-20 |
40 | 2.5-25 |
50 | 3.3-33 |
65 | 5.0-100 |
80 | 6.0-150 |
100 | 10.4-240 |
125 | 25-350 |
150 | 28-450 |
200 | 52-850 |
250 | 97-1300 |
300 | 135-2000 |
Huaheng Instrument is well-known as one of the professional and credible pulse output diesel fuel turbine flowmeter vortex flowmeter manufacturers and suppliers in China for the high flexibility and good function of its products. Adhering to our principle, out factory welcomes you to buy various types of high quality and low price products from us, and OEM service is also offered.